ProProProPro----2000200020002000 mkII mkII mkII mkII MULTI-CHANNEL MIDI TO CV CONVERTER Operating manualOperating manualOpe
9Gate from Notes - this allows the selected auxiliary output to give a voltage output in response to notes on any MIDI channel you select - the off a
10LFO x WAVESHAPE # (1 to 9 as below, default: triangle[1]) - sets the wave shape for the LFO 1, Triangle 2, Sawtooth up 3, Sawtoo
11Note type; Divide ratio; CPQN Crotchets 24 1 Crotchet triplets 16 Quavers 12 2 Quaver triplets 8
12POLY NOTE ASSIGN (Regular Cyclic, Memory Cyclic, Reset, default: Regular Cyclic) - This parameter sets how incoming MIDI notes are assigned to voi
13STORE TO MEMORY (Memory #1 to 24, default: 1) - having changed all the parameters to suit your setup, you can use this option to save these settin
14Pro-2000 mkII SYSEX INFORMATION The first five bytes of sysex for the Pro-2000 mkII are always the same for all data types [ 1 ] 0
15 specified memory location and also to the edit buffer (current setup) the data will be immediately utilised and the display will be updat
16 2Bh Ax2 max val / scale 0 > 64 > 127 { 5 } 2Ch Ax2 reset val 0 > 64 > 127 { 5 } 2Dh Ax2 lfo con
17 { NOTES } { 1 } Data 0 - 15 corresponds to MIDI channels 1 - 16 { 2 } 232 = -24 semitones 0 = no transpose 24 = + 24 semitones - 25
18Pro-2000 mkII KADI/Wasp Connector; (Pro-2000 mkII end of cable) 15 way high density D plug (viewed from terminals). 123456789101112131415 Wasp wir
1 INTRODUCTION The Kenton Electronics Pro-2000 mkII multi channel MIDI to CV converter, has been designed to give you maximum flexibility, whilst
19 MIDI Controller Numbers (for reference) Controller Number Control Function Decimal Hex 0 00H Bank switch MS
20 SPECIFICATIONS Power; 230v AC 50Hz (170v - 260v) or 115v AC 50/60Hz (85v - 130v) - See note below. 6 Watts Dimensions; 280mm
2CHANNEL C, MIDI channel filter This is used to rechannelize or filter MIDI data. Connect the synth to the Pro-2000 mkII MIDI out socket, and set
3* INC and DEC - scroll through parameters or values, depending on which mode the unit is in. * SELECT - (1) toggles between Parameter and Value for
4This socket has several modes, which are selectable in software, you may have to adjust this to receive optimum performance from you
5To speed up editing - if you are holding the INC button and want to go faster, press the DEC button too, this will step about twice as fast, similar
6CV x PORTAMENTO RATE (or TIME) (0 to 127, default: 98) - sets the speed at which portamento glides between notes. Note that 0 is fastest rate but
7DIGITAL OUTPUT PARAMETERS ChC DATA FILTER MIDI Receive Channel (1 to 16, default: 3) - sets the MIDI receive channel for the MIDI channel filter
8AUXILIARY OUTPUTS THE FOLLOWING PARAMETERS ARE THE SAME FOR EACH AUXILIARY 1 TO 6 (where x is the auxiliary number) AUX x AUX OUTPUT x Rece
Commentaires sur ces manuels